The JX3-AI4 module is an expansion module for connecting analog sensors.
The JX3-AO4 module is an expansion module for connecting analog actuators.
The EtherCAT® bus node JX3-BN-EC is a gateway between an EtherCAT® master and JX3-I/O modules by Bucher Automation.
JX3-BN-EC modules are used for the purpose of setting up distributed I/O stations. They enable synchronous communication between controller and distributed JX3 peripheral modules via EtherCAT®.
This product is at the end of its product life cycle. It is recommended not to use it for new projects anymore. Series deliveries are still possible until 30 November 2027.From 11 December 2027, this product may only be placed on the market as a spare part due to the CRA (Cyber Resilience Act). Please use the following alternative products: JX3-CN-EC or JX4-BN-EC.The Ethernet bus node JX3-BN-ETH is for setting up remote I/O stations. This module allows synchronous communication between controllers and the remote I/O station via standard Ethernet.
The JX3-CNT is a versatile counter module and supports the following modes: single-channel counter, dual-channel counter, and Synchronous Serial Interface (SSI).
The JX3-DI16 module is an expansion module for connecting digital sensors.
The JX3-DIO16 is an expansion module for connecting of digital sensors and actuators.
The strain gage module JX3-DMS2 is an expansion module for measuring strain, force and pressure. This expansion module supports all strain gages working in accordance with the principle “Strain-resistance effect of electrical conductors”. Strain gages are connected in 4-wire technology.
The JX3-DO16 module is an expansion module for connecting digital actuators.
The multi-purpose expansion module JX3-MIX1 provides you with a combination of commonly required I/O functions. This module is ideal for cost-sensitive applications.
The JX3-PS1 module provides power supply for JX3 peripheral modules.
The expansion module JX3-THI2-RTD is equipped with two inputs for analog temperature sensors of the type Pt100 or Pt1000. The temperature sensors can be connected in 2-, 3- or 4-wire technology.
The expansion module JX3-THI2-TC is equipped with two inputs for thermocouple-type temperature sensors. The following thermocouple types can be connected: J, K, B, E, N, R, S, T.
The input expansion module JX4-AI4I is used for connecting analog sensors with a current interface.
The input expansion module JX4-AI4ID is used for connecting analog sensors with a current interface.
The input expansion module JX4-AI4V is used for connecting analog sensors with a voltage interface.
The input expansion module JX4-AI4VD is used for connecting analog sensors with a voltage interface.
The input expansion module JX4-AI8I is used for connecting analog sensors with a current interface.
The input expansion module JX4-AI8ID is used for connecting analog sensors with a current interface.
The input expansion module JX4-AI8V is used for connecting analog sensors with a voltage interface.
The input expansion module JX4-AI8VD is used for connecting analog sensors with a voltage interface.
The output expansion module JX4-AO4I is used for connecting analog actuators with a current interface.
The output expansion module JX4-AO4V is used for connecting analog actuators with a voltage interface.
The output expansion module JX4-AO8I is used for connecting analog actuators with a current interface.
The output expansion module JX4-AO8V is used for connecting analog actuators with a voltage interface.
The EtherCAT® bus node JX4-BN-EC is a gateway between an EtherCAT® master and Bucher Automation JX4-I/O modules. The JX4-BN-EC is used to set up decentralized I/O stations. This module enables synchronous communication via EtherCAT® between the controller and decentralized JX4-I/O modules.
The JX4‑CNT8 detects 24‑V pulse signals up to 100 kHz on eight independent channels, counts them with 32‑bit counters, and additionally determines the pulse frequency per channel. Each channel can be activated or deactivated separately and reset. A 15‑stage input filtering suppresses interference.
The input expansion module JX4-DI16 is used to connect digital sensors.
The input and output expansion module JX4-DI16DO16 is used to connect digital sensors and actuators.
The input expansion module JX4-DI32 is used to connect digital sensors.
The output expansion module JX4-DO16 is used to connect digital actuators.
The output expansion module JX4-DO32 is used to connect digital actuators.
The JX4‑ENC2 is a module for the detection of two 5‑V differential incremental encoder signals. It supports 1‑, 2‑ and 4‑fold evaluation and determines the speed. An individual modulo range can be configured. Position values can be stored by means of fast sample inputs.
The JX4‑SSI2 evaluates two SSI absolute encoders with binary or Gray code at a clock frequency of up to 2 MHz. Fast sample inputs enable the storing of position values.
The expansion module JX4-THI4 features inputs for temperature measurement using Pt100/Pt1000 resistance thermometers or alternatively thermocouples of types J, K, B, E, S.
The expansion module JX4-THI8 features inputs for temperature measurement using Pt100/Pt1000 resistance thermometers or alternatively thermocouples of types J, K, B, E, S.
The JXM-CE-60A central electrical unit offers a simple and efficient way to wire complex agricultural machinery. The ISOBUS cable can be connected directly to the central electrical unit. Power and ISOBUS signals are distributed from the unit to various devices, such as the JCM-501 controller and up to six EA modules of the JXM-IO-EX series.
For easy commissioning and diagnostics, an ISOBUS terminal can be connected directly to the ISOBUS via an InCab connector on the central electrical unit. In addition, the unit features four relays for switching high-current loads, such as work lights. All loads are protected by easily accessible fuses.
The JXM-HMI is a universal HMI with three robust push encoders. It is therefore ideally suited for a wide range of dosing and control applications in mobile machinery.Thanks to its compact design, it can be flexibly mounted in the driver's cab either individually or, for example, in combination with a JetViewMobile 104. CANopen® ensures compatibility with the overall vehicle architecture and communication with the rest of the electronics. The comprehensive functions of the push encoders leave nothing to be desired in terms of adaptation to the application: Bidirectional rotation and a push button enable, for example, precise dosing of products to be applied. Instead of the push encoders, customer-specific adaptation with illuminated membrane keys (up to 16 keys) is possible.The integrated LEDs ensure that the functions of the individual push encoders are clearly visible at all times thanks to the respective symbols. The LEDs can also be dimmed for individual adaptation to the periphery or lighting conditions at day and night. This ensures excellent user-friendliness.
The large number of individually configurable I/O connections, the high total current as well as the rugged and compact design make the JXM-IO-E02 a multi-purpose CAN remote node.
The supply voltage of the inputs and outputs is divided into Standard Feed and Protected Feed, and it allows for independent deactivation of inputs and outputs in safety applications.
The CAN ID of the I/O node can be defined via external connection of digital inputs. This way, up to nine nodes can be addressed within one system without further configuration measures to be taken.
The expansion module JXM-IO-E11 has been designed for signal processing in the dashboard or in the driver's cabin.
20 digital switching signals, 3 analog joystick axes and a 4-way switch can be combined to be transmitted to the controller as a CAN message.
Up to 24 LEDs can be controlled via CAN in parallel. Out of these, 20 LEDs can be dimmed individually. This way, a balanced background lighting within the HMI can be set, even if different light sources are used.